Axon Synapse HDR07 Техническое руководство - Страница 12
Просмотреть онлайн или скачать pdf Техническое руководство для Усилитель Axon Synapse HDR07. Axon Synapse HDR07 18 страниц. Re-clocking hdsdi distribution amplifiers
6 Status Menu
Introduction
The status menu indicates the current status of each item listed
below. There are no defaults for status indicators. Status depends
of input signals being present or not.
Input
This status item indicates the presence of a valid SDI or HDSDI
signal at the input. Input indicates if an input signal is
Present, or Loss.
The default status of Input is Present if the input is present.
PLL
The PLL status item indicates if the PLL is Locked or
Unlocked.
The default status of PLL is Unlocked in the absence of an
input.
HD_SD
The status item HD_SD indicates if the incoming signal is SD
(Standard Definition) or HD (High Definition).
The default status of HD_SD is HD if an HD signal is input.
PLLrate
PLLrate incicates the rate at which the PLL is locked. The
range of locking rates is as follows 143Mb/s, 177Mb/s,
270Mb/s, 360Mb/s, 540Mb/sand 1485Mb/s.
The default status of PLLrate is 1485Mb/s if an HD signal is
input.