Product
Installation
WARNING! This unit is for outdoor use only.
• Do not install near any combustibles such as wood structures, fuels, clothing, fabrics, or dry vegetation.
• Installation shall be performed by a licensed contractor. All aspects of installation must conform to local
or national codes, or in the absence of codes, with Natural Fuel Gas Code ANZI Z223.1.
• An approved gas valve or keyed valve shall be installed in the decorative bowl or upstream of the unit and
located in an accessible area that is within 5ft from the APF Manual System.
Note: All APF Manual Systems includes pre-installed key valve, unless otherwise specified.
• The approved gas valve must be located where they can be easily accessible so that the gas can be shut off
quickly in case of an emergency.
Installation
1. Install the Fire Feature as shown in Figure 1 and Figure 2.
2. 24"- 60" Geo Round, 24"- 48" Legacy Round, 24"- 36" Geo Square, 30"- 36" Legacy Square requires
installation of the APF Mounting Bracket to secure the vessel and allow for ventilation and drainage. Install
the mounting bracket as shown in Figure 1. Using appropriate anchor bolts, (not supplied), secure the APF
bottom bracket to a suitable, stable permanent surface. Place the GFRC vessel over the bottom bracket so the
all thread is accessible from top of vessel. Attach the APF top ring bracket using the supplied bolts. Do not seal
open space between mounting bracket and vessel. Warranty is voided if the mounting bracket is not installed
on required models.
Figure 1
APF BOTTOM
MOUNTING BRACKET
ANCHOR BOLTS (NOT SUPPLIED)
SUPPLIED NUTS
AND WASHERS
NOTE: Drainage MUST be provided in the bottom of each bowl.
APF TOP
RING BRACKET
GFRC VESSEL
4