FIAP Aqua Active Plus
Cleaning the pump
Unscrew the pump from the UVC water housing. Unscrew the pump lid by turning counter-clockwise,
then remove the rotor. Clean all components using clean water and a brush. After cleaning the pump,
reassemble in the reverse order.
Replacing the UVC lamp
For an optimum filter performance, we recommend to replace the UVC lamp after approx. 8000
operating hours.
Important: Only use lamps the identification and capacity data of which correspond to the information
on the type plate.
Assembly of the unit
Tighten the pump at the UVC water housing using the union nut. Ensure that the hose is not kinked.
Insert the UVC clarifying unit including the pump. Attach the top strainer casing and press it onto the
bottom strainer casing until the clamps engage in the bottom strainer casing. Important: Lead the
connection cable through the cable opening in the bottom strainer casing and route the cable such that
pinching is avoided.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit
for damage. Store the unit immersed in water or filled with water at a frost-free place. Do not flood the
power plug!
Wearing parts
The UVC lamp and the rotor are wear parts and are excluded from the warranty.
Disposal
Dispose of the unit in accordance with the national legal regulations. The UVC lamp needs special
disposal. Ask your specialist dealer.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
9
www.fiap.com
FIAP Aqua Active Plus
Malfunctions
Malfunction
Cause
The unit is not operating
No mains voltage
Delivery or fountain height
Flow regulator excessively
insufficient or not consistent,
throttled
cloudy water
Nozzle blocked
Excessive pressure losses in
the hoses
Intake openings blocked
Rotor blocked
Pond extremely dirty
Quartz glass tube soiled
UVC lamp does not light up
UVC lamp defective
Unit switches off after a short
Water temperature too high
running period
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
Remedy
Check mains voltage
Set flow regulator
Clean nozzle
Reduce hose length and
connecting parts to a minimum,
route hoses as straight as
possible
Clean housing
Clean rotor
Remove algae and leaves from
the pond, perform a partial
water change
Remove UVC filter and clean
the quartz glass tube
Replace the UVC lamp
Note maximum water
temperature of + 35 °C
10
www.fiap.com