Просмотреть онлайн или скачать pdf Примечание по установке для Переключатель Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion. Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion 46 страниц. Distributed forwarding card 4 for ws-x68xx, ws-x69xx, and select ws-x67xx modules
Также для Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion: Примечание по установке (14 страниц), Руководство по решению (17 страниц), Белая книга (19 страниц), Описание (1 страниц), Бюллетень продукции (6 страниц), Уведомление (4 страниц), Информационный лист (9 страниц), Информационный лист (18 страниц), Белая книга (18 страниц), Руководство по конфигурации (8 страниц), Примечание по установке (28 страниц), Руководство по устранению неполадок (11 страниц), Примечание по установке (18 страниц), Руководство пользователя (17 страниц), Примечание по установке (24 страниц), Руководство (19 страниц), Примечание по установке (36 страниц)

Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion Примечание по установке
Note
If your chassis does not have the system ground attached, you must install the system ground lug.
Refer to the online Catalyst 6500 Series Switches Installation Guide for the procedure.
Note
After you install the system ground lug, follow these steps to correctly attach the ESD wrist strap:
Attach the ESD wrist strap to bare skin as follows:
Step 1
If you are using the ESD wrist strap supplied with the FRUs, open the wrist strap package and
a.
unwrap the ESD wrist strap. Place the black conductive loop over your wrist and tighten the strap
so that it makes good contact with your bare skin.
If you are using an ESD wrist strap equipped with an alligator clip, open the package and remove
b.
the ESD wrist strap. Locate the end of the wrist strap that attaches to your body and secure it to your
bare skin.
Grasp the spring or alligator clip on the ESD wrist strap and momentarily touch the clip to a bare metal
Step 2
spot (unpainted surface) on the rack. We recommend that you touch the clip to an unpainted rack rail so
that any built-up static charge is then safely dissipated to the entire rack.
Attach either the spring clip or the alligator clip to the ground lug screw as follows (See
Step 3
If you are using the ESD wrist strap that is supplied with the FRUs, squeeze the spring clip jaws
a.
open, position the spring clip to one side of the system ground lug screw head, and slide the spring
clip over the lug screw head so that the spring clip jaws close behind the lug screw head.
Note
If you are using an ESD wrist strap that is equipped with an alligator clip, attach the alligator clip
b.
directly over the head of the system ground lug screw or to the system ground lug barrel.
78-15893-08
This system ground is also referred to as the network equipment building system (NEBS)
ground.
You do not need to attach a supplemental system ground wire to the system ground lug; the
lug provides a direct path to the bare metal of the chassis.
The spring clip jaws do not open wide enough to fit directly over the head of the lug screw
or the lug barrel.
Catalyst 6500 Series Distributed Forwarding Card 3 for WS-X67xx Modules Installation Note
Attaching Your ESD Grounding Strap
Figure
31):