Digital Data Communications Level One GTL-2091 Руководство - Страница 9
Просмотреть онлайн или скачать pdf Руководство для Переключатель Digital Data Communications Level One GTL-2091. Digital Data Communications Level One GTL-2091 14 страниц. Stp optional characteristic configuration commands
Также для Digital Data Communications Level One GTL-2091: Руководство (6 страниц), Руководство (5 страниц), Руководство (18 страниц), Руководство (9 страниц)
Step5
ethernet
frame
{
symbols
{symbols}} | window symbols}
Step6
ethernet
frame-period {threshold {high
{
symbols
{symbols}} | window symbols}
Step7
ethernet
frame-seconds {threshold {high
{
symbols
{symbols}} | window symbols}
http://www.level1.com
The window size ranges between 10 and 600 on a
1000M Ethernet interface and its default value is 10
in this case, while the window size ranges between
1 and 60 on a 100M Ethernet interface and its
default value is 1 in this case.
oam
link-monitor
Sets the high and low thresholds of the error frame
{threshold
{high
event, which triggers the link events of error frame.
|none}
|
low
The threshold high parameter is used to configure
the high threshold. Its unit is signal number. It
ranges between 1 and 65535 and its default value
is none.
The threshold high parameter is used to configure
the low threshold. Its unit is signal number. It ranges
between 0 and 65535 and its default value is 1.
The window parameter is used to configure the
window size of the round-query period. Its unit is
second. It ranges between 1 and 60 and its default
value is 1.
oam
link-monitor
Sets the high and low thresholds of the period event
of error frame, which triggers the link events of error
|none}
|
low
frame period.
The threshold high parameter is used to configure
the high threshold. Its unit is signal number. It
ranges between 1 and 65535 and its default value
is none.
The threshold high parameter is used to configure
the low threshold. Its unit is signal number. It ranges
between 0 and 65535 and its default value is 1.
The window parameter is used to configure the
window size of the round-query period. The unit of
the window size is the number of the 14881 frames.
The window size ranges between 100 and 6000 on
a 1000M Ethernet interface and its default value is
100 in this case, while the window size ranges
between 10 and 600 on a 100M Ethernet interface
and its default value is 10 in this case.
oam
link-monitor
Sets the high and low thresholds of the second
event of error frame, which triggers the link events
|none}
|
low
of error frame's second.
The threshold high parameter is used to configure
the high threshold. Its unit is signal number. It
ranges between 1 and 900 and its default value is
none.
The threshold low parameter is used to configure
the low threshold. Its unit is signal number. It ranges
between 0 and 900 and its default value is 1.
The window parameter is used to configure the
OAM Configuration
- 7 -