Cisco 7606 Руководство пользователя - Страница 8
Просмотреть онлайн или скачать pdf Руководство пользователя для Сетевое оборудование Cisco 7606. Cisco 7606 28 страниц. User guide
Также для Cisco 7606: Брошюра (8 страниц)
Catalyst 6509/Cisco 7606/Cisco 7609 Cryptographic Module
Table 1
LED
STATUS
SYSTEM
ACTIVE
POWER MGMT Green
SWITCH LOAD
PCMCIA
LINK
Catalyst 6509 Switch, Cisco 7606 Router, and Cisco 7609 Router with VPN Services Module Certification Note
8
Catalyst 6509 Switch and Cisco 7606 and 7609 Router LEDs
Color/State Description
Green
All diagnostics pass. The module is operational (normal
initialization sequence).
Orange
The module is booting or running diagnostics (normal initialization
sequence).
An over-temperature condition has occurred. (A minor temperature
threshold has been exceeded during environmental monitoring.)
Red
The diagnostic test failed. The module is not operational because a
fault occurred during the initialization sequence.
An over-temperature condition has occurred. (A major temperature
threshold has been exceeded during environmental monitoring.)
1
Green
All chassis environmental monitors are reporting OK.
Orange
The power supply has failed or the power supply fan has failed.
Incompatible power supplies are installed.
The redundant clock has failed.
One VTT
threshold has been exceeded.
Red
Two VTT modules fail or the VTT module temperature major
threshold has been exceeded.
The temperature of the supervisor engine major threshold has been
exceeded.
Green
The supervisor engine is operational and active.
Orange
The supervisor engine is in standby mode.
Sufficient power is available for all modules.
Orange
Sufficient power is not available for all modules.
If the switch is operational, the switch load meter indicates (as an
approximate percentage) the current traffic load over the backplane.
The PCMCIA LED is lit when no Flash PC card is installed in the
slot, and it goes off when you insert a Flash PC card.
Green
The port is operational.
Orange
The link has been disabled by software.
Flashing
The link is bad and has been disabled due to a hardware failure.
Orange
Off
No signal is detected.
2
module has failed or the VTT module temperature minor
3