Checking the LEDs on the Ethernet Line Cards
• 10 Gigabit Ethernet Line Card (XGLC)
Each Ethernet card is equipped with status LEDs:
• Run/Fail
• Active
• Standby
In addition to the status LEDs, each network interface is equipped with:
• Link
• Activity
The possible states for all LEDs on the Ethernet line cards are described in the sections that follow.
Ethernet Line Card Run/Fail LED States
The Run/Fail LEDs on the Ethernet Line Cards indicate the overall status of the cards. These LEDs are
illuminated steady green during normal operation.
If the LED is not green, use the troubleshooting information in the table to diagnose the problem.
Table 16: Ethernet Line Card Run/Fail LED States 7
Color
Green
Red
None
ASR 5000 Installation Guide
20
Description
Troubleshooting
Card powered with no
None needed.
errors detected
Card powered with
Errors were detected during the POSTs. It is likely that the errors
error(s) detected
were logged to the system's command line interface during the
boot process.
Refer to the System Administration Guide for troubleshooting
information.
Card is not receiving
Verify that the POWER LEDs on the PFUs are green. If they are
power
not, refer to
troubleshooting information.
Verify that the power source is supplying ample voltage and
current to the chassis.
Verify that the card is properly installed per the instructions in
this document.
If all of the above suggestions have been verified, it is possible
that the line card is not functional. Please contact your service
representative.
Applying Power and Verifying the Installation
Checking the LED on the PFU, on page 5
for