Cisco ASR 5000 Руководство по установке - Страница 29

Просмотреть онлайн или скачать pdf Руководство по установке для Шлюз Cisco ASR 5000. Cisco ASR 5000 37 страниц. Applying power and verifying the installation
Также для Cisco ASR 5000: Руководство по установке (18 страниц), Руководство по установке (33 страниц), Процедура установки (8 страниц)

Cisco ASR 5000 Руководство по установке
Applying Power and Verifying the Installation

Channelized Line Card Run/Fail LED States

The Run/Fail LED on the Channelized line card indicates the overall status of the card. These LEDs are
illuminated steady green during normal operation.
If the LED is not green, use the troubleshooting information in the table to diagnose the problem.
Table 25: Channelized Line Card Run/Fail LED States
Color
Green
Red
None

Channelized Line Card Active LED States

The Active LED on the channelized line card indicates that the operating software is loaded on the card and
that the card is ready for operation.
Installed line cards remain in ready mode until their corresponding packet processing card is activated during
configuration. While in ready mode the Active LED is off. After the packet processing card is activated, the
line card installed in the upper-rear chassis slot behind the packet processing card is also activated. The line
card installed in the lower-rear chassis slot behind the packet processing card enters standby mode.
If the LED is not green, use the troubleshooting information in the table to diagnose the problem.
Description
Troubleshooting
Card powered with no
None needed.
errors detected
Card powered with
Errors were detected during the POSTs. It is likely that the errors
error(s) detected
were logged to the system's command line interface during the
boot process.
Card is not receiving
Verify that the POWER LEDs on the PFUs are green. If they are
power
not, refer to
troubleshooting information.
Verify that the power source is supplying ample voltage and
current to the chassis.
Verify that the card is properly installed per the instructions in
this document.
If all of the above suggestions have been verified, it is possible
that the line card is not functional. Please contact your service
representative.
Card-Level LEDs on the Channelized (STM-1/OC-3) Line Card
Checking the LED on the PFU, on page 5
ASR 5000 Installation Guide
for
29