Cisco ASR 9000 Series Руководство по конфигурации - Страница 38

Просмотреть онлайн или скачать pdf Руководство по конфигурации для Шлюз Cisco ASR 9000 Series. Cisco ASR 9000 Series 46 страниц. Line card
Также для Cisco ASR 9000 Series: Настройка параметров сети (26 страниц), Руководство по конфигурации (50 страниц), Руководство (24 страниц), Настройка (46 страниц), Руководство (44 страниц), Краткое справочное руководство (7 страниц)

Cisco ASR 9000 Series Руководство по конфигурации
How to Configure Clear Channel T3/E3 Controllers and Channelized T1/E1 Controllers
2.
3.
4.
5.
6.
DETAILED STEPS
Step 1
configure
Example:
RP/0/RSP0/CPU0:router# configure
Step 2
controller {t1 | e1} interface-path-id
Example:
RP/0/RSP0/CPU0:router(config)# controller t1
0/1/1/0/1/1
Step 3
lnm {major-warning | remove}[clear |
set][line-code-violation lcv-value
[path-code-violation pcv-value]][duration
seconds]
Example:
RP/0/RSP0/CPU0:router(config-t1)# lnm
major-warning
Step 4
lnm minor-warning [clear |
set][line-code-violation lcv-value
[path-code-violation pcv-value]][duration
seconds]
Example:
RP/0/RSP0/CPU0:router(config-t1)# lnm
minor-warning
Cisco ASR 9000 Aggregation Services Router Interface and Hardware Component Configuration Guide
482
Configuring Clear Channel T3/E3 and Channelized T3 and T1/E1 Controllers on the Cisco ASR 9000 Series Router
controller {t1 | e1} interface-path-id
lnm {major-warning | remove} [clear | set][line-code-violation lcv-value [path-code-violation
pcv-value]][duration seconds]
lnm minor-warning [clear | set][line-code-violation lcv-value [path-code-violation
pcv-value]][duration seconds]
lnm syslog
end
or
commit
Enters global configuration mode.
Enters T1 or E1 configuration mode.
(Optional) Enables link noise monitoring and specifies
thresholds for noise errors on T1/E1 links that are used to
signal major warning events or link removal and recovery
from those events.
The default values for both set and clear thresholds are:
For T1 links—line-code-violation is 1544,
path-code-violation is 320, and duration is 10.
For E1 links—line-code-violation is 2048,
path-code-violation is 831, and duration is 10.
(Optional) Enables link noise monitoring and specifies
thresholds for noise errors on T1/E1 links that are used to
signal minor warning events and recovery from those
events.
The default values for both set and clear thresholds are:
For T1 links—line-code-violation is 154,
path-code-violation is 145, and duration is 10.
For E1 links—line-code-violation is 205,
path-code-violation is 205, and duration is 10.
OL-32684-01