DIGIWAY PTY P550 Руководство по эксплуатации - Страница 8
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Открыватель двери гаража DIGIWAY PTY P550. DIGIWAY PTY P550 13 страниц. Sliding gate motor
Также для DIGIWAY PTY P550: Руководство по эксплуатации (12 страниц)
6. Inverter settings
When the gate stops, the inverter's display is opening high-speed frequency and flash. This frequency
can be changed by up and down arrows on the inverter. The following form is the inverter's standard
setting for the automatic gate application. Not mentioned function keep as factory setting.
Function
Acceleration time
Deceleration time
Freq. Upper limit
Freq. Lower limit
SP1 Frequency
Start/Stop/Control
Multifunction Input
Multifunction output
SP2 Frequency
SP3 Frequency
7. Limit switch option
From Software version 4.3 add on limit switch input option. If no limit switch connected, the controller
previous version
works as
or reached pre-set gate length, whichever happen first. It can use one limit switch, either open or close,
or two limit switch, both open and close.
With limit switch, the controllers will automatically CLRER the encoder counting errors when every
time hit limit switch, while without limit switch (previous version) and the controller ONLY clear the
encoder counting error when recycle power.
Here is the limit connection diagram.
Limit switch can be N/O, it can be magnetic, mechanical switch or proxy (PNP, 3 or 5 wires)
When turn DIP2 ON, Open Limit input OLM as open PEB input N/C. When gate in opening cycle if
open PEB is block, gate will stop pen until PEB is clear. Close Limit input CLM as safety switch input
N/C. When safety switch is active, gate will not run.
DIGIWAY PTY LTD
INVERTER SETTING
F
Function Description
1
Acceleration time
2
Deceleration time
6
Max. Frequency
7
Min. Frequency
8
Gate Close High Speed
10
Terminals
20
Reset Terminal Function
21
When inverter runs, relay on
26
Gate Open Low Speed
27
Gate Close Low Speed
. If add limit switch, the controller will stop gate either hit limit switch
8
Setting Unit Note
2.0-2.5
Sec.
2.0
Sec.
60
Hz
0
Hz
35
Hz
1
6
1
Hz
20
Hz
15
Hz