Toshiba ASYG14LMCB Руководство по эксплуатации - Страница 5

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Кондиционер Toshiba ASYG14LMCB. Toshiba ASYG14LMCB 48 страниц.

Timer Operation

Note for timer settings:
Any interruption of the power supply, such as a blackout or cutting off of a circuit breaker, makes the set internal clock go wrong.
In such a case, the TIMER indicator on the indoor unit blinks, and you need to readjust the setting.
ON timer or OFF timer
Turn on the indoor unit by pressing the START/STOP button.
1
OPERATION indicator on the indoor unit turns on.
If the indoor unit is already operating, skip this step.
Press the ON timer button or the OFF timer button.
2
Clock indicator on the remote controller display starts blinking,
and TIMER indicator on the indoor unit turns on.
Adjust the time by pressing the SELECT button within about 5
3
seconds, while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to
standby screen.)
To cancel the timer and return to the normal operation, press the
CANCEL button.
To redo the timer setting, perform step 2 and 3.
Program timer (combined use of the ON timer and the OFF timer)
You can set an integrated ON–OFF or OFF–ON timer.
Either of the timer whose confi gured starting time is closer to the
current time works fi rst, and the order of timer operation is displayed
as follows:
Timer
ON–OFF timer
OFF–ON timer
The timer that is set later starts counting down after the counting
down of the preceding timer is fi nished.

General Informations on Operation

Automatic defrosting operation
When outdoor temperature is very low with high humidity, frost
may form on the outdoor unit during the heating operation, and
it could reduce the operating performance of the product.
For frost protection, a microcomputer-controlled automatic
defrost function is equipped in this air conditioner.
If frost forms, the air conditioner will temporarily stop, and
defrost circuit will operate briefl y (maximum of 15 minutes.)
OPERATION indicator on the indoor unit blinks during this
operation.
If frost forms on the outdoor unit after the heating operation, the
outdoor unit will stop automatically after it operates for a few
minutes. Then the automatic defrosting operation starts.
Auto-restart function
In event of power interruption such as a blackout, the air
conditioner stops once. But it restarts automatically and
performs previous operation when the power supply is resumed.
If any power interruption occurs after the timer is set, counting
down of the timer will be reset.
After the power supply is resumed, the TIMER indicator on the
indoor unit blinks to notify you that there has been a timer fault.
In such a case, reset the timer for your opportune time.
Malfunctions caused by other electrical devices:
Use of other electrical appliances such as an electric shaver or
nearby use of a wireless radio transmitter may cause the malfunction
of the air conditioner.
If you encounter such a malfunction, turn off the circuit breaker once.
Then turn it on again, and resume operation by using the remote
controller.
9333003061_OM.indb 5
9333003061_OM.indb 5
Indicator on remote controller display
AIR CONDITIONER Wall Mounted Type
Notes:
• If you change the setting value for the timer after the program timer
is set, the counting down of the timer will be reset at that moment.
• Time setting for each combination should be within a span of 24 hours.
SLEEP timer
Press the SLEEP timer button to activate the SLEEP timer.
1
OPERATION indicator and TIMER indicator on the indoor unit
turns on.
Adjust the time by pressing the SELECT button within about 5
2
seconds, while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to
standby screen.)
Each time you press the button, the time changes as follows:
0.5
1.0
2.0
(30 min.)
To repeat the timer, press the SLEEP timer button when
indicator is not displayed on the remote controller display.
To help you to fall asleep comfortably and prevent excessive warming
or cooling in sleep, the SLEEP timer controls the temperature setting
automatically in accordance with the set time shown as follows. The
air conditioner completely turns off after the set time has elapsed.
In HEAT mode
1 °C 2 °C 3 °C 4 °C
Set
30 min.
temperature
1 hour
1.5 hour
Set time
OPERATING MANUAL
3.0
5.0
7.0
9.0
hours
In COOL or DRY mode
Set time
1 hour
1 °C
2 °C
En-5
20/09/2013 10:10:13
20/09/2013 10:10:13