Ariston ST 100 ProTech Инструкции по установке, обслуживанию и эксплуатации - Страница 26

Просмотреть онлайн или скачать pdf Инструкции по установке, обслуживанию и эксплуатации для Водонагреватель Ariston ST 100 ProTech. Ariston ST 100 ProTech 36 страниц. Unvented hot water storage cylinders
Также для Ariston ST 100 ProTech: Инструкция по установке и использованию (24 страниц), Руководство пользователя (16 страниц), Инструкции по установке, обслуживанию и эксплуатации (34 страниц)

Ariston ST 100 ProTech Инструкции по установке, обслуживанию и эксплуатации
5.

MAINTENANCE

5.1
p
t
ro
ecH
A
-
nti
corrosion
5.2
t
c
-
HerMAl
ut
5.3
i
H
MMersion
eAter
5.4
u
c
nventeD
ontrols
26
To ensure efficient and safe operation, and to maintain the warranty, it is
necessary to ensure the appliance is serviced annually by a competent
person.
Before servicing, preliminary electrical system checks must be carried out to
ensure electrical safety (i.e. polarity, earth continuity, resistance to earth and
short circuit).
wArninG: SWITCH OFF THE POWER SUPPLY BEFORE WORKING ON
THE APPLIANCE.
s
ysteM
trouble-shooting:
1) The green L.E.D. is NOT on:
- Check to see that the circuits electric plug is connected (if not,
- Check to see that the P.C.B, is supplied with electricity (if not, replace
- Check to see that 230 V electricity is supplied (if not, ensure that 230 V
- If all these checks fail to locate the problem, replace the electronic
2) The red L.E.D. is on:
- Check to see that the tank is filled with water (if not, fill it before
- Check to see that the clip-on circuit connector is in the proper position
- Check to see that the electrodes connection lead is property connected
- Check to see that the connection lead to the tank is properly connected
- Check to see that the two leads from the clip-on circuit connector are
- If all these checks fail to locate the problem, replace the electronic
n
ote
1) Disconnect the two supply cables from the P.C.B. to the supply terminal;
2) Disconnect the clip-on circuit connector and polarising slot which
connects the circuit to the tank and the electrode;
3) Disconnect the P.C.B. from its supporting plate (plastic clips in the 4
corners) and;
4) Replace the defective circuit with a new one, then re-install in reverse
order to the above.
If the thermal cut-out has operated the cause must be found before resetting
(
)
out
s
(see section 6).
(
)
Should the immersion heater(s) become scaled, we would recommend that
s
the immersion heaters be replaced, a scale reducer be fitted on the cold
water supply to the cylinder and that the thermostat is set below 60
prevent further scale formation.
Check controls as per the following:
1) Line strainer - with the water supply turned off remove screen from
strainer and clean off any debris;
2) Expansion vessel - with the water supply turned off and taps open, check
expansion vessel pressure and top up as necessary;
3) Temperature & pressure relief valve - with the water supply turned on,
check manually by lifting the test lever/turning the test knob (ensure valve
connect);
the supply cable);
is supplied);
circuit (installer).
carrying out the following checks);
(if not, position correctly);
(to check this, gently pull on it) (if not, replace the electrode);
to the tank (if not, connect properly); .
not damaged, stripped, etc. (if so, replace the electrode);
circuit.
: To replace the P.C.B, there is no need to drain the cylinder;
O
C to