Ariston UNO Руководство по установке - Страница 6

Просмотреть онлайн или скачать pdf Руководство по установке для Котел Ariston UNO. Ariston UNO 17 страниц. Wall-hung combination boiler

400
123,5 123,5
200
200
68
65
67
67
65
F
. 2.0
IG
450
*A minimum distance of 20mm is required to each side
F
. 2.1
IG
of the boiler to allow removal of the outer casing.
220 mm
F
. 2.2
IG
135
68
116
acqua
gas
120
250
20
20
85 mm
2.3
O
D
VERALL
IMENSIONS
L
:
EGEND
A = Central Heating Flow (3/4")
B = Domestic Hot Water Outlet (1/2")
C = Gas Inlet (3/4")
D = Domestic Cold Water Inlet (1/2")
E = Central Heating Return (3/4")
2.4
C
LEARANCES
In order to allow for access to the interior of the boiler for
maintenance pur poses, the boiler must be installed in
compliance with the minimum clearances indicated in F
2.5
M
OUNTING THE
Fasten the boiler in place using the template and anchors
supplied with the unit. It is highly recommended that a
spirit level be used to position the boiler so that it is
perfectly level.
For additional information, please consult the instructions
contained in the connection kit and the flue kit.
2.6
E
C
LECTRICAL
For safety purposes, have a competent person carefully
check the electrical system in the proper ty, as the
manufacturer will not be held liable for damage caused by
the failure to earth the appliance properly or by anomalies
in the supply of power. Make sure that the residential
electrical system is adequate for the maximum power
absorbed by the unit, which is indicated on the rating plate.
In addition, check that the section of cabling is appropriate
for the power absorbed by the boiler.
The boiler operates with alternating current, as indicated in
the technical information table in section 6, where the
maximum absorbed power is also indicated. Make sure
that the connections for the neutral and live wires
correspond to those indicated in the diagram. The
appliance electrical connections are situated on the
reverse of the control panel (see the servicing manual for
further information)
I
!
MPORTANT
In the event that the power supply cable must be changed,
replace it with one with the same specifications. Make the
connections to the terminal board located within the
control panel, as follows:
- The yellow-green wire should be connected to the
terminal marked with the "
use the ferrule mounted on the other supply cord;- The
blue wire should be connected to the terminal marked "N";
- The brown wire should be connected to the terminal
A
PPLIANCE
ONNECTION
" symbol; make sure to re-
. 2.1
IG
6