6. Opens the required ports for audio and signaling. These ports are, by default:
SIP signaling PORT (SIP LOCAL PORT): 5060
Ports for audio transmission and control (RTP and RTCP protocols): 5004
and 5005, respectively.
STUN ports: 3478 & 3479.
2. CONNECTING AND CONFIGURING THE EQUIPMENT
The physical connection will be done to a LAN port.
Connect the network cable to the LAN1 port at the back of the AEQ Phoenix
Mobile. Connect the other end to the Ethernet port to the router LAN port.
Connect at least a microphone and a pair of headphones to the front audio XLR
connectors of the Phoenix Mobile
Connect the power supply cable to the AEQ Phoenix Mobile. If it is equipped
with a battery pack and mains power is not available, you can omit this step.
Press the ON button at the left side of AEQ Phoenix Mobile. Verify that the main
display is illuminated.
Verify, at the back of the unit, that the green LED at the right of the Ethernet
port starts blinking indicating that the IP connection is active.
Configuring the Ethernet port and assignation of Program channel:
Make sure that we are selecting "Program" in the main screen (the one
representing faders and vumeters). At the lower center area you should read
"Program". Also, by pressing MENU we enter the Wizard menu that should
have a PROGRAM legend at the top center area. If COORDINATION appears
instead in any of both places, just press Channel key and channel will be shifted
to PROGRAM.
APLICACIONES ELECTRONICAS QUASAR S.A.
TEL: (34) 91 686 13 00 - FAX: (34) 91 686 44 92 - E-mail: [email protected] - Web:
www.aeq.eu
2