Whirlpool UXT3036AY Инструкция по установке и руководство по эксплуатации и уходу - Страница 8

Просмотреть онлайн или скачать pdf Инструкция по установке и руководство по эксплуатации и уходу для Вентиляционная вытяжка Whirlpool UXT3036AY. Whirlpool UXT3036AY 32 страницы. 30" (76.2 cm) and 36" (91.4 cm) range hood
Также для Whirlpool UXT3036AY: Инструкции по установке и руководство по эксплуатации и уходу (36 страниц), Инструкции по установке и руководство по эксплуатации и уходу (28 страниц)

Whirlpool UXT3036AY Инструкция по установке и руководство по эксплуатации и уходу
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4 " x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines
" (1.3 cm) and 4 " (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
Wall Venting
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
"
(0.9 cm)
"
(9.8 cm)
(13.3 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to Round Vent Transition
Roof Venting
To make a 4 " x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines
" (1.3 cm) and 4 " (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
8
* " (1.3 cm)
5 / "
*4 "
(13.3 cm)
(12.1 cm)
5 / "
(13.3 cm)
" (0.9 cm) and 3 " (9.8 cm)
Centerline
5 "
5 "
(13.3 cm)
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
(12.1 cm)
*From wall, not cabinet frame
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Circular vent opening
*5"
(12.7 cm)
*From wall, not
cabinet frame
Style 3 - Cut Openings for 7" (17.8 cm) Round Vent
To make a circular vent openings on the underside of the
cabinet top and bottom:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top and bottom of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
*5"
(12.7 cm)
*From wall, not
cabinet frame
* " (1.3 cm)
5 / "
*4 "
(13.3 cm)
5 / "
(13.3 cm)
Cabinet
cutouts
7 / " (18.4 cm) diam.
cabinet cutouts