1. Introduction
Mercury Advance SMARTcare is an innovative solution in the prevention and treatment of pressure
ulcers. It offers effective dual therapy in a single surface by combining advanced, clinically proven
technologies previously only available in separate hybrid surfaces. Advanced air displacement
technology incorporated into a unique 4 zone configuration now provides more effective pressure
redistribution.
When used in non-powered mode, clinically proven advanced air displacement technology
continually optimises and improves pressure redistribution in response to patient body weight and
movement. The unique 'air only' heel zone effectively offloads pressure on the vulnerable heel area.
When used in powered/dynamic mode Mercury Advance SMARTcare delivers pressure relief via
a series of connected alternating foam and air cells. Unencumbered by a top layer of foam on the
mattress, the unique 'foam in air cell' construction ensures the delivery of effective pressure relieving
therapy. Dependant on clinical judgement, the alternating function can be operated on either a Low or
High Pressure
The digital Control Unit controls air flow into, or out of the air cells as required according to the
selected operating mode. It also maintains the air pressure within the mattress at the required level
and controls the action of the Audible/Visual Warning System in the event of mains supply failure or
over or under inflation pressure.
2. Quick Reference Guide
This is a quick reference guide for the Mercury Advance SMARTcare System
Product Code MAT1610001
Power Switch Audible Warning Reset
The power switch simply switches the mains power to the Control Unit on and off.
When the Control Unit detects an Audible Warning condition, this can be silenced (see page 5)
and re-set by switching the Control Unit off and then back on again.
CPR Tag and Dual Function Connector
Please ensure that both the CPR Tag located on the umbilical and the Dual
Function Connector are always placed fully home, prior to inflating the mattress.
NB: The mattress will NOT inflate properly should this not be the case.
The CPR Tag is only to be used in the event of a clinical emergency for priority use.
However, disconnecting this function will rapidly deflate air from the mattress
in readiness for transport / static mode.