Cleaning and Maintenance
Unit Motor is hermetically sealed with a super quality resin and does not require
any extra care. The only serviceable part is the impeller. The impeller assembly
rest in an easy to open cover that needs to be spot checked for dirt, grime and
mineral build up. Should you discover any worn or damaged areas replace
impeller immediately to restore pump to its full capacity. Pumps ran in salt water
should also be flushed with freshwater after use and before maintenance. It is
recommended that these inspection take place ever 2-3 months depending on
water conditions.
SYMPTOM
The pump doesn't run
The motor repeats on
and off immediately
without pump running.
The motor suddenly
stops and cannot be
started again.
The pump runs normally
at the beginning but the
water flows out slowly
or there is no water.
Replacement Part Information
Replacement parts for your pump are available for purchase online. Please visit
our website at www.ecoplususa.com for more information. The following parts are
available:
Part #
748451
EcoPlus
748456
EcoPlus
748461
EcoPlus
748461
EcoPlus
748471
EcoPlus
Troubleshooting
CAUSE
Power is not turned on
Plugged in insufficiently
Impeller binding
Apply to wrong voltage
The water inflow or outflow
pipe is clogged with foreign
matters
Impeller worn out
Water level does down and
the pump exposed on the
water source
Hose is too long or clogged
with foreign matter
There is air in the impeller
chamber (Only when used
outside water.)
Description
Mag Drive 250PGH Replacement Shaft and Impeller
®
Mag Drive 350PGH Replacement Shaft and Impeller
®
Mag Drive 500PGH Replacement Shaft and Impeller
®
Mag Drive 700PGH Replacement Shaft and Impeller
®
Mag Drive 900PGH Replacement Shaft and Impeller
®
10
RESOLUTION
Turn on power
Plug in sufficiently
Remove foreign matters from impeller
Apply to correct voltage
Remove foreign matters from pipes
Replace it with a new one
Put pump into water
Shorten the hose or clean up inside
In order to get rid of air, put the pump
into the water. Turn the switch to "ON"
then "OFF" intermittently 2 or 3 times.
MSRP
$17.99
$17.99
$17.99
$23.99
$23.99