Alemite 343684 Руководство по установке и обслуживанию - Страница 6
Просмотреть онлайн или скачать pdf Руководство по установке и обслуживанию для Блок управления Alemite 343684. Alemite 343684 12 страниц. Fluid solenoid valve and pulse meter kit
Function and
overhaul*
Refer to Troubleshooting (page 11) to
determine where to look if problems occur.
Disassembly
Switch module
1 Remove screws (2) that secure switch
module (1) to housing (3) († Fig. 4).
2 Separate switch module from housing.
NOTE
Switch module is serviced as an
assembly. No further breakdown of
assembly is necessary.
Metering gears
3 Remove screws (8) and washers (7) that
secure housing cover (6) to housing (3).
4 Separate housing cover from housing.
5 Remove o-ring (4) from oval groove in
housing.
6 Remove gears (5) from housing.
Clean and inspect
7 Clean all metal parts in cleaning solvent.
Solvent should be environmentally safe.
8 Inspect all parts for wear and/or
damage. Replace as necessary.
9 Closely inspect mating surfaces of
housing cover (6) and housing (3) for any
imperfections. Ensure a smooth and
clean contact is obtained when
assembled.
NOTE
Use a repair kit for replacement parts.
Do not discard old components. First,
verify all component are included in kit.
*
Indicates change.
Pulse meter
6
1
2
3
4
5
6
7
8
Fig. 4