SEWER
CLEANOUT
ALARM FLOAT CONDUIT
INSTALLED BY CONTRACTOR
WHERE APPLICABLE
Figure 10
1.
This product must be connected to a grounded, metallic,
permanent wiring system, or an equipment-grounding terminal
or lead on the product.
2.
Place the blower where it is easily accessible for maintenance
and inspection.
3.
Install the blower in an area where it will be protected from
damage and inundation. Also make certain the location has good
ventilation.
4.
Install the blower on a foundation that is level and solid.
5.
Excavate trenches for one air line from blower to the unit, and
conduit from Fusion to control panel.
MACHINED PIPE FOR
AIR HOOK UP
Figure 11
BLOWER INSTALLATION AND PLACEMENT
ALARM PANEL
WARNING!

BLOWER

OPTIONAL SEPTIC TANK INSTALLATION
MAY BE REQUIRED BY
LOCAL OR STATE REGULATIONS
ZFL TREATMENT UNIT
HIGH WATER FLOAT CONDUIT
TO BE INSTALLED BY
CONTRACTOR
!
WARNING
ELECTRICAL SHOCK
HAZARD
CONDUIT TO
PANEL SEAL
AFTER LINE
INSTALLATION
CLARUS FUSION ®
ALARM PANEL
ALARM FLOAT
CONDUIT
© Copyright 2014. All rights reserved.
RISER AND LID
AIR LINE
6.
Install one air line from the blower to the unit. Length of piping
must be less than 17' (5 m). If distances from 17' (5 m) to 33' (10
m) are required, upsize by one pipe size (Figure 11). If longer air
lines needed, consult the factory.
7.
The blower is provided with one discharge port. Attach the barbed
end of the PVC tee (included in the blower box) to the blower
using the rubber elbow.
8.
Attach the small diameter black air tubing (included in the blower
box) to barbed fitting on PVC tee. Black air tubing and blower
cord should be routed to the control panel through conduit. Attach
the black air tubing line to the air pressure sensor barbed fittings
in the panel.
9.
Connect the remaining end of the PVC tee to the airline installed
in Step 6.
BLOWER
POWER
CORD
AIR LINE
TO PANEL
ADAPTER
RUBBER
AIR LINE
ELBOW
TO PANEL
AIR LINE TO
FUSION ®
9
TO DISPERSAL
DRILL HOLES FOR
BLOWER MAKE UP AIR
SPRING
CLAMPS
DECORATIVE ROCK CONFIGURATION
INTERIOR CONFIGURATION
SK2928
SK2929