Lenovo Flex System X6 Compute Node Руководство по эксплуатации - Страница 28

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Сервер Lenovo Flex System X6 Compute Node. Lenovo Flex System X6 Compute Node 36 страниц. Compute node

Physical specifications

Dimensions and weight (approximate) for one X6 compute node:
Width: 435 mm (17.1 in.)
Height 56 mm (2.1 in.)
Depth 500 mm (19.7 in.)
Maximum weight: 12.25 kg (27 lbs)

Supported environment

The Flex System X6 Compute Node complies with ASHRAE Class A3 specifications.
This is the supported operating environment:
Power on:
Temperature: 5 to 40 °C (41 to 104 °F)
Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8 - 85% relative humidity
Maximum dew point: 24 °C (75 °F)
Maximum altitude: 3048 m (10,000 ft.)
Maximum rate of temperature change: 5 °C/hr (41 °F/hr)
Power off:
Temperature: 5 to 45 °C (41 to 113 °F)
Relative humidity: 8 - 85%
Maximum dew point: 27 °C (80.6 °F)
Storage (non-operating):
Temperature: 1 to 60 °C (33.8 to 140 °F)
Altitude: 3050 m (10,006 ft.)
Relative humidity: 5 - 80%
Maximum dew point: 29 °C (84.2°F)
Shipment (non-operating):
Temperature: -40 to 60 °C (-40 to 140 °F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5 - 100%
Maximum dew point: 29 °C (84.2 °F)
Flex System X6 Compute Node (7903)
28