Lenovo Flex System X6 Compute Node Руководство по эксплуатации - Страница 26
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Сервер Lenovo Flex System X6 Compute Node. Lenovo Flex System X6 Compute Node 36 страниц. Compute node
Light path diagnostics panel
For quick problem determination when you are physically at the server, the compute node offers a 3-step
guided path:
1.
The Fault LED on the front panel
2.
The light path diagnostics panel
3.
LEDs next to key components on the system board
The light path diagnostics panel is visible when you remove the server from the chassis. The panel is at
the upper right side of the compute node, as shown in the following figure.
Figure 9. Location of X6 light path diagnostics panel
To illuminate the light path diagnostics LEDs, power off the compute node, slide it out of the chassis, and
press the power button. The power button doubles as the light path diagnostics remind button when the
server is removed from the chassis. The meanings of the LEDs are listed in the following table.
Table 15. Light path diagnostic panel LEDs
LED
Meaning
LP
The light path diagnostics panel is operational.
S BRD
A system board error is detected.
MIS
A mismatch has occurred between the processors, DIMMs, or HDDs.
NMI
A non-maskable interrupt (NMI) has occurred.
TEMP
An over-temperature condition occurred that was critical enough to shut down the server.
MEM
A memory fault has occurred. The corresponding DIMM error LEDs on the system board are also lit.
ADJ
A fault is detected in the adjacent expansion unit (if installed).
Flex System X6 Compute Node (7903)
26