Dispens-a-Matic Bottle-Matic II Информация и инструкции - Страница 3

Просмотреть онлайн или скачать pdf Информация и инструкции для Упаковочное оборудование Dispens-a-Matic Bottle-Matic II. Dispens-a-Matic Bottle-Matic II 3 страницы. Labeler / applicator

1. Flip toggle switch to down position for two label application.
Flip switch to down
position for two label
application
Setting the push dial for your front/back labels:
1) Measure the circumference of the bottle.
2) Measure the total length of both labels (include the gap between labels on the roll)
3) Subtract the total label length from the circumference and divide by 2
4) Subtract .5 from the number determined in step 3
Example: If your circumference is 9.42" and your labels total 5"
9.42" – 5" = 4.42" divided by 2 = 2.21
2.21 minus .5 = 1.71 Set dial to 1.7 (you may have to make minor adjustments using the number on the right of
dial up or down to reach best location)
NOTE: If gap between labels is less than ½" (.5) you will need to add the result from #1 (circumference) into
the total.
Example: If your circumference is 5.25" and your labels total 3.75"
5.25"- 3.75" = 1.5 divided by 2 = .75 minus .5" = .5 plus 5.25 = 5.5 Set dial to 5.5
For Bottle-Matic II (front/back)
Call with ANY questions:
Dispensa-Matic Label Dispensers
28220 Playmor Beach Rd
Rocky Mount, MO 65072 USA
Phone: 1-573-392-7684 FAX: 1-573-392-1757
Per example formula set dial to 1.7
Page | 3