CAME 319U36EN Руководство по установке - Страница 11
Просмотреть онлайн или скачать pdf Руководство по установке для Панель управления CAME 319U36EN. CAME 319U36EN 19 страниц. Control panel for 24v gearmotors
8 Settings
- END ADJ/SENS.
- AMP SENS.
- SLOWDOWN/AMP SENS
- OP TIME
- ACT
* Warning!: minimum sensitivity = maximum power
Adjusting the opening stop micro-switch.
Swing the door open until it is about30 mm from the fully-open position.
Turn the cam until the micro-switch is inserted, and lock it using the screw.
* End adjustement of amperometric sensor during travel:min/max.
* Adusts the amperometric sensitivity which controls the force developed by the motor during
movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of
travel.
* Adusts the amperometric sensitivity which controls the force developed by the motor during
movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of
travel.
Adjusts the closing strike zone.
Adjusts the waiting time when open.Once this time elapses, automatic closing is triggered.The waiting
time can be adjusted to between 2 and 120 seconds.
Cam
Micro-switch
Cam fastening
screw