ASSEMBLY
1. Install the new o-rings making sure the grooves are clean.
2. Apply o-ring lubricant on the outside face of the sight glass to reduce
friction. Position the new sight glass as shown in figure 5, making sure
that the edge with the chamfer will pass the o-rings first, then press the
sight glass evenly into the bore. If necessary use the old sight glass to
push down the new sight glass.
3. Insert retaining ring into the groove in the body.
4. Verify the new seals and sight glass do not leak by capping one end and
applying low air pressure (3 to 5 PSI) and checking for air bubbles
under water.