After being prompted by the guided trouble-shooting procedure, add
terminal 15 and terminal 30 with the F1 and F2 keys. The switching
status of the terminals is indicated by the green LEDs next to the keys.
When the LED is lit, the associated terminal carries voltage (12 Volts).
The electricity is connected to the BMS via the diagnostics port and via
the adapter cable.
Select the CAN termination impedance indicated by the guided trouble-
shooting procedure by repeatedly pressing the CAN-R select (F3) key.
The respectively selected impedance value is indicated by the yellow
LED on the selection row. The measurement adapter is now ready for
communication. Now follow the instructions from the guided trouble-
shooting procedure.
When prompted by the guided trouble-shooting procedure to perform
the "Close Connection" function, press and hold the F4 key on the
measurement adapter for 5 seconds until the blinking "ready" status
LED lights up steadily. Now press the F4 key once again within an
additional 5 seconds, therefore triggering the "Close Connection"
function. This activates the "Close Connection" function. This supplies
terminal 30C with on-board power and the pilot line is closed.
The "Closed" LED now also lights up as a confirmation and the power
supply to terminal 30C drops off.
Pressing the F4 key once again resets the function and the connection is
reopened. This causes the function LEDs to go dark.
The device is shut down by pressing the green On button once.
www.akkuteam.de
26

4.8 Firmware update

NOTE! When a firmware update is made available for
download, the download contains separate operating
instructions for installing the update.
The firmware status of the measurement adapter can be updated.
In order to upload an update revision of the firmware/software,
connect the VAS 5581 to a Windows PC via its USB port. Each new
firmware revision comes with its own detailed instructions.
The firmware revision is published by the sales organization or can be
obtained as a download from akkuteam.
www.akkuteam.de

4.9 Supplied content

1 VAS 5581 Measurement Adapter
1 VAS 5581-1 Adapter cable
1 Power supply - 18 Volt 4.75 A (90-240 VAC 50/60 Hz)
1 Power cable - EU
1 Operating manual
1 Carrying case
27
V 1.0