VSG/VSGX Installation & Maintenance
Electrical Activation & Wiring Instructions
Electrical gates must be connected to a low-voltage power source to operate. The following instructions detail the steps to setup on
electrical connection for the fail-safe locking gates.
Wiring at the Gate Location
1.
Plug the power supply into a wall outlet and verify it is delivering the expected 2A at 12VDC.
2.
Unplug the power supply.
3.
Connect the wires from the power supply to the wires from the magnetic lock. The magnetic lock wires will be hanging down
from inside the latch post. The diagram below shows which wires should be connected to each other. If you need to extend the
cable length, use 18 AWG cable. Total cable length should not exceed 50 feet or be wrapped in coils.
4.
On the gate-side of the conduit, install crimp connector receptacles on the conduit wire leads. These will receive the connectors
provided on the lock leads coming from the bottom of the latch post.
5.
On the gate-side of the conduit, connect the positive red-colored wire coming from the bottom of the latch post to the positive
conduit lead wire. Connect the negative black-colored wire coming from the bottom of the latch post to the negative conduit lead
wire.
Connecting a Switch Box
Refer to the diagram below if you will be controlling the gate with a momentarily normally closed switch.
12VDC/2A
Power Supply
Normally
Closed Switch
PUD2996R4-0
Lock Wires
Positive
18 AWG Cable
50' Max Length
For assistance: [email protected] +1 (909) 591-8431
Power Supply Wires
Latch Post