Dodge 078289 Руководство по эксплуатации - Страница 6

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Промышленное оборудование Dodge 078289. Dodge 078289 8 страниц.

Dodge 078289 Руководство по эксплуатации
Hydraforce RV08-20H-0-N5/.75
CAUTION: Dodge recommends the oil temperature to be
70°F or above before equipment operation.

MAINTENANCE

Periodically check the oil level in the bearing housings and the
Cool Lube 2 to ensure proper operation.
Most foreign material in a system flushes to the reservoir after
the first few hours of operation. We recommend that you drain
the tank, replace the fluid, change the filter, and clean the suction
strainer after 3-5 hours of operation. After the initial cleaning,
the strainer should be cleaned at a minimum of every 4000 hours
of operation. More frequent cleaning is required if the system is
used in a highly contaminated atmosphere such as a foundry or
paper mill.
After the initial replacement, the supply line filter should be
replaced periodically as required by operating conditions. Check
the visual clog indicator on the filter head between filter changes
to ensure the filter is not being bypassed.
NOTE: Cool Lube 2 Units manufactured after September
2016 utilize a new relief valve for the pressure line only.
Previous Relief Valve: Hydraforce RV08-20H-0-N-5/.75
New Relief Valve: Fulflo VJ-3R/HS/WS
For Cut Sheets of each valve, contact manufacturers.
Figure 7 - Relief Valves
6
Fulflo VJ-3R/HS/WS
IN
MN3082