PL6800ST
USAGE / TROUBLESHOOTING GUIDE
Complete details are in your operator's manual,
but below are a few quick tips for efficient operation.
What happens when I connect a battery and commence a charge routine?
In most cases, the charger will move through the initial energizing phase and move directly into bulk charge mode.
If the battery is severely discharged, the charger will enter Soft Start Mode. This will slow the charging process.
If the battery is heavily sulfated (damaged), the charger will enter Battery Repair Mode. This will slow the charging process.
When to test?
Because time is critical, as soon as the green CHARGE COMPLETE LED lights, the battery can be tested.
Although the amber light is flashing, the battery Is at a very high state of charge and can be tested.
How to set the charger's display?
We suggest, when first connecting a battery, that the display is in the "VOLTS" display mode. This allows you see the
battery's voltage immediately. If voltage is below 10V, the charger will enter Soft Start Mode. If voltage is below 1V,
forced start override is required (see point 3 on front page). Once charging has started, switching over to "% CHARGE"
display mode allows the operator to see charging progress.
Display goes dark – Energy Save Mode.
During a charge routine, after 10 minutes of no button presses, the display will power down to save energy.
Charging continues through this mode. Simply press the Display button to wake the control panel up.
Reverse Polarity Connection
If the reverse polarity ERROR LED lights, power OFF charger immediately and correct connections.
Over-Temperature Condition
If the charger shows an ERROR light and FAn on the display, the unit has detected an overheat condition and shut down.
Allow unit to cool for 10 minutes. Confirm fan operation. Confirm unit is well ventilated with ample clear space around it.
Flashing ERROR LED – Over-Voltage Condition
Battery voltage is >16V. Unit will not allow charging operation. Set display to " VOLTS" display mode and confirm voltage.
If the battery is a nominally rated 12V battery, the battery has a critical error. If not 12V, do not use the charger to charge it.
Phase Time Out – Flashing ERROR LED + Flashing CHARGING LED
Charge time exceeded – likely a damaged battery. Confirm battery is a nominally rated 12V battery.
Circuit Beaker Trips
During a 100A charging cycle, maximum input current is required by the charger. The PL6800ST requires a 20A AC circuit
(17A max current draw). Make sure other devices on the circuit are not causing an overload of the circuit. Test the charger
in 10A charge mode – if it functions properly, suspect other loads or circuit not delivering 20A.
For additional product support details, scan the QR Code on the front side of this
sheet to visit our page dedicated to the PL6800ST
.
804-680-500