ASHAPOWER ROVER-5000LV-48V Руководство пользователя - Страница 13

Просмотреть онлайн или скачать pdf Руководство пользователя для Инвертор ASHAPOWER ROVER-5000LV-48V. ASHAPOWER ROVER-5000LV-48V 14 страниц. Solar mppt pcu

ASHAPOWER SOLAR -PCU- ROVER SERIES
MENU
SOL-ABSN-V
16
SOLAR CHG.ABSORPTION VOLT
SOL-BULK-V
17
SOLAR CHG. BULK VOLT
SOL-MAX-AMP
18
LIMIT TOTAL OUTPUT AMP
BAT-MAX-AMP
19
LIMIT CHG. AMP TO BATTERY
CAL-PSWD-0
CAL-PSWD-1
20
CAL-PSWD-2
CAL-PSWD-3
FACT-RESET
21
RESTORE FACTORY SETTINGS
TYPE OF
SETTINGS
Limit the absorption charging voltage limit for the connected
batteries.Default value given is for C10 grade lead acid batteries.
CUSTOMER
( whenever the battery voltage goes below the float voltage the
SETTINGS
the device enters again to bulk and absorption charging modes
and ret urns to float level and maintains acid gravity)
Limit the maximum bulk charging voltage recommended for the
CUSTOMER
batteries.This value varies in di erent types of batteries.Default value
SETTINGS
given is for C10 grade solar Lead acid batteries.For SMF and Gel
batteries this value is between 13.5V to 14.5V (Refer battery user manual
CUSTOMER
Limit the total output current from the charge controller to the battery
SETTINGS
and connected load
Limit the charging current to the battery if needed. (maximum charging
current is recommended as 20% of the Ah of a single 12V lead acid battery.
CUSTOMER
Eg: for a 150Ah battery,30 ampere is the maximum charging current
SETTINGS
recommended. Refer battery user manual before changing the value
ADVANCED SYSTEM SETTINGS
TECHNICIAN
SETTINGS
CUSTOMER
To reset all settings to factory settings change the default
SETTINGS
value from "0" to "1"
MAIN FUNCTION SETTINGS
DESCRIPTION
WITH PASSWORD
Vers.5.1
RANGE
MIN
DEFAULT
MAX
11 V
14V
16V
13V
14.6V
16.5V
30A
50A
50A
40A
0A
50A
-
1
0