OPERATION MANUAL 
Desktop CO2, Temperature & 
Relative Humidity Monitor   
TIM‐12 
 
INTRODUCTION 
Thank you for purchasing the TIM12 desktop 
CO2 monitor. It measures carbon dioxide levels, 
air temperature and humidity. This makes it 
ideal for indoor air quality (IAQ) diagnosis and 
HVAC system performance verification. 
 
Poor indoor air quality is considered unhealthy. 
It can lead to drowsiness, inability to 
concentrate, and even illness. 
 
IAQ monitoring of CO2 levels is widely used in 
public areas such as offices, classrooms, 
factories, hospitals and hotels. It is also 
recommended for industrial hygiene in some 
countries. (See appendix). 
Product Features: 
● Large display shows CO2 level, temperature, 
    humidity, date and time 
● 15 degree tilt angle makes the display easy 
    to see and read 
● Indoor air quality level indication: 
    Good, Normal, and Poor 
● Stable NDIR sensor for CO2 detection 
● Visible and audible CO2 warning alarm 
● ABC (Automatic Baseline Calibration) 
    or manual CO2 calibration 
● Maximum or minimum CO2 level recall 
● Sampling rate from 1 sec. to 4:59:59. 
 
MATERIALS SUPPLIED 
This package contains: 
● Meter 
● Power Supply (5V +/‐ 10%, >= 0.5A) 
● USB cable and software CO 
● Manual 
 
POWER SUPPLY 
The meter is powered by an AC adaptor 
(5V/0.5A output). 
 
LCD DISPLAY 
 
Symbols 
ppm                  CO2 level in parts‐per‐million 
GOOD                CO2 is in good level 
NORMAL            CO2 is in normal level 
POOR                CO2 is in poor level 
Air Temp.          Air temperature 
Humidity %        Unit of air relative humidity 
o
E (C/F)              Celsius/Fahrenheit of temp. 
MAX/MIN          Maximum/Minimum readings 
                          CO2 alarm icon 
 
 
NOTE:   
TWA / STEL / VENT.R / are vain icons on this 
 
model. 
 
 
KEYPAD 
SET ‐Enter setup mode 
‐Save and finish settings 
ESC‐Exit setup page / mode 
      ‐Terminate calibration/data logging 
RESET ‐ Clear MAX/MIN values 
LOG▲‐ Select mode, increase value at setup 
‐ Start data logging 
MIN/MAX▼
‐Activate MAX, MIN function 
‐Select mode or decrease value 
during setup 
SET+▲+MIN/MAX▼ ‐ CO2 calibration mode 
 
OPERATION 
POWER ON/OFF 
Plug the wall adaptor into an appropriate 
receptacle. The meter will turn on automatically 
after a short beep. The lit LED indicates full 
power. If the voltage is too high or low, "bAt" 
will display on the LCD and the LED will flash. 
See page 14 for trouble shooting. 
 
During normal operation, the LCD will display 
the current CO2 level in ppm, air quality level, 
air temperature, humidity, and the current date 
and time (Fig.1). 
 
 
 
 
 
 
 
 
 
 
 
 
TAKING MEASUREMENTS 
The meter starts taking measurements 
immediately after it is turned on and updates 
the readings every second. In the event the 
operating environment is quickly changed (for 
example, from high to low temperature), it will 
take approximately 2 minutes for the CO2 and 
temperature to adjust and 10 minutes for 
humidity to stabilize. 
NOTE: Do not hold the meter close to your face 
as your breath will affect the CO2 level. 
 
MIN/MAX 
While the meter is powered on, press the 
"MIN/MAX▼" button to see the minimum and 
maximum CO2 level, temperature, and 
humidity in turn. Each press of "MIN/MAX" will 
display the MIN and MAX values in order, then 
return the meter to normal mode (Fig.2). 
 
During normal operation or while viewing 
MIN/MAX levels, press and hold the 
"RESET" key for more than 1 second to clear the 
stored minimum and maximum values. 
 
 
 
 
 
 
 
 
 
INTERNAL DATA LOGGING 
Press "LOG▲" for 2 seconds under normal mode 
to start logging. The green LED blinks to indicate 
the logging status and the LCD shows the real 
time CO2 value and "rEC". Lower displays are 
the real time temperature, humidity and clock. 
 
To terminate data logging, press "ESC" for 2 
seconds, The LED light will stop blinking and the 
display will show "End" and CO2 reading 
interchangeably. Hold down "ESC" for 2 
seconds again, and it will return to normal 
measurement mode.   
 
The meter can save CO2, temperature and 
humidity levels over time in internal memory. 
The memory capacity is 15,999 points. The 
sampling rate can be from 1 second to 4 hours 
59 minutes and 59 seconds (See SETUP). 
Minimum and Maximum recall is still available 
during logging. 
 
 
 
 
 
HIGH CO2 ALARM