Aktakom ATK-2040 Kullanıcı Kılavuzu - Sayfa 6
Ölçüm Cihazları Aktakom ATK-2040 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Aktakom ATK-2040 10 sayfaları. Ac/dc trms watt clamp meter
WARNING: Make sure that all the test leads are disconnected from the meter's terminals for current measurement.
1. DC Current
a. Set the rotary switch at 400A DC.
b. Push the zero button to adjust the reading to zero.
c. Press the trigger to open the jaw and fully enclose the conductor to be measured. No air gap is allowed between
the two half jaws.
d. Read the measured value from the LCD display.
2. AC Current
a. Set the rotary switch at 400A AC
b. Press the trigger to open the jaw and fully enclose the conductor to be measured. No air gap is allowed between
the two half jaws.
c. Read the measured value from the LCD display.
B. DC/AC Voltage Measurements
WARNING: Maximum input for DC V is 600, and for AC V is 600. Do not attempt to take any voltage
measurement that exceeds the limits. Exceeding the limits could cause electrical shock and damage to the
clamp meter.
www.tmatlantic.com