American Standard 1748 Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 4

Küvetler American Standard 1748 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. American Standard 1748 16 sayfaları. Aths with integral apron
Ayrıca American Standard 1748 için: Teknik Özellikler (2 sayfalar), Kullanım ve Bakım Talimat Kılavuzu (10 sayfalar)

American Standard 1748 Kurulum ve Kullanım Talimatları Kılavuzu
• CONSULT A QUALIFIED PLUMBER TO HOOK-UP THE
DRAIN/OVERFLOW PLUMBING TO THE HOUSE WASTE
SYSTEM. USE INSTRUCTION SUPPLIED WITH DRAIN AND
OVERFLOW.
Deck-mounted Faucet:
FOR DECK-MOUNTED FAUCET AND FILL SPOUT, USE A
HOLE SAW FOR DRILLING. APPLY MASKING TAPE TO
PROTECT THE SURFACE PRIOR TO DRILLING TO AVOID
DAMAGE. FOLLOW THE MANUFACTURER'S INSTRUCTIONS
FOR SPACING AND SIZE OF HOLES TO BE DRILLED. BE
SURE TO LOCATE THE FILL SPOUT SO THAT THE FLOW OF
WATER DOES NOT STRIKE HANDLES OR OTHER SURFACES
WHICH MAY CAUSE THE WATER TO SPLASH. THE PLUMBING
FOR THE FAUCET AND FILL SPOUT SHOULD NOT BE
ALLOWED TO INTERFERE WITH THE WHIRLPOOL
EQUIPMENT.
Consult a qualified electrician for the following hook-up.
Failure to do this will affect your warranty.
A separate 115 VAC 15 amp 60Hz service is required for
Whirlpool Systems
Warning – When using electrical products, basic
precaution should always be followed,
including the following:
1. DANGER: RISK OF ELECTRICAL SHOCK. CONNECT ONLY
TO A CIRCUIT PROTECTED BY A 15 AMP
GROUND-FAULT-CIRCUIT INTERRUPTER (GFI)
2. GROUNDING IS REQUIRED. THE UNIT SHOULD BE
INSTALLED BY A QUALIFIED ELECTRICIAN AND
GROUNDED.
A GREEN COLOURED TERMINAL (OR WIRE CONNECTOR
MARKED "G" , "GR" , OR "GROUNDING") IS PROVIDED WITHIN
THE TERMINAL COMPARTMENT. TO REDUCE THE RISK OF
SHOCK, CONNECT THIS TERMINAL OR CONNECTOR TO THE
GROUNDING TERMINAL OF YOUR ELECTRIC SERVICE OR
SUPPLY PANEL WITH CONTINUOUS GREEN INSULATED
COPPER WIRE EQUIVALENT IN SIZE TO THE CIRCUIT
CONDUCTORS SUPPLYING THIS EQUIPMENT, BUT NO
SMALLER THAN NO. 14 AWG.
NOTE: BUILDING MATERIALS AND
WIRING SHOULD BE ROUTED
AWAY FROM THE PUMP
757222-A
Plumbing
Testing:
IT IS IMPORTANT TO REMOVE ALL CONSTRUCTION DEBRIS
TO ENSURE THAT THE BATH IS CLEAN BEFORE TESTING.
BE SURE TO TEST THE WHIRLPOOL BATH AFTER THE
ELECTRICAL AND PLUMBING ARE COMPLETE, BEFORE
ENCLOSING THE BATH AND COMPLETING THE
SURROUNDINGS. THIS TEST ENSURES THAT NO DAMAGE
OCCURRED DURING SHIPMENT OR INSTALLATION AND
THAT THE INSTALLATION IS SATISFACTORY. FAILURE TO DO
THIS WILL AFFECT YOUR WARRANTY COVERAGE.
FILL THE BATH TO AT LEAST 1" ABOVE THE HIGHEST JET.
ALLOW THE WATER TO STAND FOR 30 MINUTES. CHECK
THE DRAIN AND WASTE/OVERFLOW FOR LEAKS. TURN ON
THE WHIRLPOOL JETS AND RUN FOR 20 MINUTES. CHECK
FOR LEAKS WHILE SYSTEM IS UNDER PRESSURE.
Electrical
A PRESSURE WIRE CONNECTOR IS PROVIDED WITHIN THE
TERMINAL BOX TO PERMIT CONNECTION OF A NO. 8 AWG
SOLID COPPER BONDING CONDUCTOR BETWEEN THIS
UNIT AND ALL OTHER ELECTRICAL EQUIPMENT AND
EXPOSED METAL IN THE VICINITY, AS NEEDED TO COMPLY
WITH LOCAL REQUIREMENTS.
SEPARATE 15 A, 115 V, 60HZ POWER SUPPLY CIRCUIT
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT
INTERRUPTER (NOT INCLUDED).
Fused disconnect
switch or circuit
breaker (not included).
Refer to name plate on
motor for the maximum
ampere rating to size
circuit conductors and
protective devices
according to national
and local electrical
codes. Where the code
requires it, ground the
motor frame by a No. 8
AWG copper conductor
attached to bonding lug
on motor.
Warning – Pumps must be installed on factory
(4)
Single-pole switch
(out of reach from
bath – note that code
may restrict position
of switch).
Terminal box on bath.
This box may be
relocated and securely
fastened near the
access panel.
115 V pump motor.
provided mounting.