Doorentryonline SR2-X Kullanıcı Kılavuzu - Sayfa 6

Kart Okuyucu Doorentryonline SR2-X için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Doorentryonline SR2-X 12 sayfaları. Proximity, wiegand & mifare card reader with remote control

PROGRAMMING
Programming will vary depending on your access configuration. Please follow the instructions according to
your access configuration
General Programming Information – Two ways
1) Remote Control: Please use the Infrared Remote Control to program the Reader. The infrared
receiver head is near the LED, so when you program the reader, please direct the Remote Control to
the LED (Factory default code: *123456#)
User ID number: Assign a User ID to the access card/key fob in order to easily delete it via the remote
control in the event it becomes lost
The common user ID number can be any number from 0-986. IMPORTANT: User ID's do not have to be
proceeded with any leading zeros, Recording of User ID's is crucial. Modifications to the user requires
the User ID to be available
2) Master Add/Delete Card to add or delete any:
Proximity Card: 125KHz industry standard EM-RFID or 13.56MHz Mifare proximity card or key fob
Sound and Light indications
Operation Status
Stand by
Enter into programming mode
In the programming mode
Operation error
Exit from the programming mode
Open lock
Alarm **
** Please see Reset Procedure for ALARM (Page 12)
Easy way
Add cards/key fobs by using the Master Add/Delete Card
Programming Step
1. Present the Master Add/Delete Card
once
Delete cards by using the Master Add/Delete Card
Programming Step
1. Present the Master Add/Delete Card
twice
Led Colour
Red light bright
Red light shines
Orange light bright
-
Red light bright
Green light bright
Red light Shines quickly
Action
Present the user card/key fob to be added
Re-present the Master Add/Delete Card to confirm
Action
Present the user card/key fob to be deleted
Present the Master Add/Delete Card to confirm
Buzzer
-
One bleep
One bleep
Three bleeps
One bleep
One bleep
Continual bleeps