DACE LUX DC12 Kurulum ve Kullanım Kılavuzu - Sayfa 4

Garaj Kapısı Açıcı DACE LUX DC12 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. DACE LUX DC12 12 sayfaları.

This is the small sec on of travel near the end of the door's closing cycle. If the operator
An -Crush Gap
receives a trigger in this sec on of travel, the door will reopen to prevent possible damage
or injury.
Auto Close
When set, this func on will enable automa c closing of the garage door a er a set period
Func on
of me.
When the force required to open the garage door is equal to the force required to close
Balanced Door
the garage door.
The main electronic circuit board housed inside the operator.
Control Board
The light, built into the operator Control Card, which switches on during each door opera on
Courtesy Light
and can also be operated by pressing a programmed bu on on a remote control.
The even distribu on of the doors opening and closing forces.
Door Balance
The steel channel housing the Chain, Li ing Assembly and Manual Release Mechanism
Drive Channel
A removable electronic component on the Control Card that protects the Control Card
Fuse
from damage in the case of severe forces being applied.
Infrared Safety
Op onal electronic sensors which prevent the garage door from closing if the infrared
Beams
beam, being transmi ed between the sensors, is blocked, indica ng an obstruc on.
Electronic alphanumeric display on the operator used to assist with programming and
LED Display
fault finding.
An electronic security feature that will prevent the door from receiving a trigger while the
Lockout
func on is ac ve.
Manual Release
The lever assembly that is used to place the garage operator into manual mode, allowing
Mechanism
for the garage door to be operated manually.
Obstacle
The detec on of an obstacle causing the mo on of the door to be impeded through the
Sensing
processing of algorithms in the garage door operator's so ware.
Onboard
An integrated part of the Control Card which receives the signal from the Remote Control
Receiver
to trigger of the operator.
Process of the operator slowing down the door's travel speed towards the end of the
Ramp Down
door's travel.
The hand held device used to ac vate the opening and closing of the operator.
Remote Control
Remote Bu on
One of several bu ons on a remote control used to ac vate various func ons.
An op onal device connected directly to the Control Card to make use of sun energy
Solar Panel
instead of a buildings mains supply for charging the operator's ba ery.
An external device connected to the buildings mains supply via a plug point that reduces
Transformer
the mains voltage to a safe voltage to charge the operators ba ery.
GLOSSARY
4
4.
Status Output (auxiliary)
The Status output is used to provide feedback from the operator on the current posi on of the Trolley on the
Drive Channel and the mains supply status. Most commonly used for the Status Output is an LED, connected to
the operator. The LED can be placed in a convenient loca on for ease of use.
It is important to understand that the Status Output only indicates the opera onal status of the operator and
not the door. To explain, imagine the door is closed and the LED indicates that the operator is closed. The door
is then placed in manual mode and opened manually, however the Trolley has not moved and remains in the
closed posi on, the LED will con nue to indicate that the status of the operator as closed. When the door is
reconnected to the Li ing Bracket (placed back in automa c mode), the status of both the door and operator
will be closed.
Refer to 'Se ng Auxiliary Output....Menu 5' for programming.
LED
OPERATOR & MAINS STATUS
ON
The operator/door is open
The operator/door is closed and the
OFF
mains is off.
BLINK The operator/door is closed and the
mains is on.
5.
Low Ba ery Output (auxiliary)
This output will provide indica on when the ba ery is low. An LED or a GSM transmi er can be used.
Refer to 'Se ng Auxiliary Output....Menu 5' for programming.
LUX DC12
Control Board
LIMITS
REV
+
ve
-
ve
LED
Open Collector
2K7
Resistor
Harness
(Double Wire)
Code: SA004
Resistor & LED not included.
6.
Trigger Output (auxiliary)
LUX DC12
The Trigger Output is used to
Control Board
trigger other external devices at
the same me that the door
operator is triggered. These
devices can include buzzers
inside the house which sound
when the garage door is
triggered. Another example is
the switching on of lights or the
External
deac va on of the home alarm
Trigger
by triggering a Pulse Stretcher.
TRIGGER
Refer to 'Se ng Auxiliary
GND
Output....Menu 5' for
programming.
LUX DC12
Control Board
LIMITS
REV
AUX LOCK 12V TRIG INF GND
+
ve
Open Collector
-
Harness
LED
ve
(Double Wire)
Code: SA004
2K7
Resistor & LED not included.
Resistor
Power
Input
AUX LOCK 12V TRIG INF GND
OR
COM
INPUT
Open Wire
GSM Module
Connector
(Single Wire)
Code: SA044
LIMITS
REV
AUX LOCK 12V TRIG INF GND
NO
DACE
Relay Module
COM
Code: SA001
21
Power
Input
Power
Input