7.
Auxiliary Light
LUX DC12
The Auxiliary Light output is
Control Board
used to connect an external light
to the operator. The external
light can be switched on when
the operator is triggered for a
preselected period of me (up
to 9 minutes) or the light can be
ac vated via a dedicated remote
bu on, without triggering the
operator. If switched on by a
External
dedicated bu on, it will remain
Light
on for a period of 1 hour but can
be switched off before 1 hour is
L
up by pressing the same bu on
again.
N
Refer to 'Se ng Auxiliary
Output....Menu 5' for
programming.
Solar panels must be mounted in direct sunlight and the
•
panel angle alignment should be adjusted for op mal
condi ons for the loca on. It is very important to ensure
that no shadows will cross the panel during the day.
It is recommended that a ba ery with a capacity of at least
•
7Ah is used.
The operator will automa cally detect that it is connected
•
to a solar supply once the panel voltage exceeds 17V DC. It
will then no longer indicate a power fail message but will
only display a single bar "_" when the panel output voltage
is too low for charging.
When connec ng a solar panel directly to the controller
•
the transformer must be removed from the input.
Solar Panel specs:
Power Ra ng:
20W min
Min Voltage output:
17V DC
Max Voltage Output:
22V DC.
ERROR
MEANING
CODE
Cause:
Low ba ery voltage. The ba ery may be faulty or an excessive number of
opera ons, or devices, may have drained the ba ery.
Remedy:
Ensure the operator is plugged in and switched on. Fully charging a 5Ah 12V
Low Ba ery
Lb
ba ery will take 24hrs if the operator is not in use and if no other devices, such as
locks; receivers & lights, are connected.
Check that connected devices are not drawing excessive currents.
Addi onal devices will reduce the number of daily opera ons and standby
opera ons.
Cause:
The operator is not detec ng an input supply voltage.
Remedy:
If using a transformer, ensure that the transformer is plugged in and switched on.
The output voltage should be between 12VAC – 18VAC, if not the transformer may
Power Fail
PF
need to be replaced.
If using a solar panel, ensure the output voltage is between 17VDC - 22VDC. When
a solar panel is connected to the operator it is necessary for the DC voltage to be
higher than 17V for the operator to switch to DC Solar Opera on a er which the
operator will stop showing the Power Fail message.
LIMITS
REV
AUX LOCK 12V TRIG INF GND
DACE
NO
Relay Module
COM
Code: SA001
CONNECTING A SOLAR PANEL
REV
AUX LOCK
12V TRIG INF GND
LUX DC12 Control Board
Not Polarity
Sensi ve
Solar Panel
ERROR CODES
CAUSE & REMEDY
22
Thank you for choosing Dura Access Control Equipment (DACE). We welcome you to the ever growing interna onal
community of DACE product owners. The advanced engineering and high-quality construc on of each DACE
product we build is something of which we are proud.
The LUX DC12 garage operator is packed with features to bring you convenience and enhance your security.
Power
Input
Your owners manual will introduce you to the features and opera on of your new LUX DC12. It is suggested that
you read it carefully since the informa on it contains can contribute greatly to the sa sfac on you receive from
your new garage door operator.
Important informa on before automa ng your garage door!
Only automate garage doors that are within specifica on and are in good working order. The door must be able
●
to be opened and closed using only one hand and, if released midway, the door should not move. The force
used to open the door by hand should be similar to that used to close the door. If the door is not in perfect
working order, it should be serviced by a qualified garage door technician prior to automa on.
Automa ng a garage door increases the risk of entrapment and crushing. While all reasonable steps have been
●
taken to ensure that your garage door operator is safe to install and operate, it must be noted that a garage
door is a heavy piece of equipment and can cause serious injury and death. Never allow children to play with or
around the garage door. Only ac vate the garage door when it is in full view and when there are no children or
Power
animals in close proximity that could get injured.
Input
We highly recommend the installa on of Infrared Safety Beams to increase the safety of the doors opera on.
●
The LUX DC12 is not waterproof and is therefore not suitable for outdoor use.
●
It is important to note that the LUX DC12 garage operator is ba ery operated and by simply switching off the
●
mains power supply to the operator it does not mean that the operator does not have power. It is therefore
important that both the mains power supply and the ba ery be disconnected before working on the operator.
Use extreme cau on when opera ng the manual release as the door may move, resul ng in injury or damage.
●
The door should be inspected every 6 months by disengaging it from the operator and moving it by hand. The
door should move easily but it should not close on its own if released. If the door is found to be defec ve, it
must remain disconnected from the operator and a qualified garage door technician be called to carry out
repairs to the door.
Please a ach your invoice to this manual for future use (see warranty)
Dura Access Control Equipment reserves the right to make changes to the products described in this manual
without no ce and without obliga on to no fy any persons or organisa ons of such revisions or changes.
Addi onally, DACE makes no representa ons or warran es with respect to this manual.
This manual may only be copied or distributed as a whole, no altera ons or subsec ons may be distributed or
copied without the prior express consent of DACE in wri ng
FOREWORD
DISCLAIMER
3