5 16 kV models
The 16 kV models dito and NSG 435 feature lightweight simulators with battery power for compliance to IEC 61000-4-2.
5.1 Operating Elements 16 kV models
1
The discharge pistol with display
2
Exchangeable tip containing
3
Buttons for adjusting settings
4
ESD Pulse Trigger
5
Exchangeable battery
5.1.1 Quick Start 30 kV Models
1)
Charge the battery fully
2)
Setup the test area according to IEC 61000-4-2 and the test plan
3)
Ensure earth cable is connected
4)
Connect the proper Air (round) or Contact (pointed) discharge tip to the front of the discharge pistol
5)
Switch on the device
NSG 435: Press and hold the yellow button to start the simulator
Dito: Press and hold the trigger to start the simulator.
Dito: Press F2 to go to Quick Start mode
6)
Press the corresponding +/- key to set the voltage
7)
Press the corresponding discharge mode (Air or Contact)
8)
Press the trigger to fire a pulse
Quick Start and Safety Guide
1
2
1
3
4
5
V 1.0
ESD Simulators
12 / 17