08. INSTALL MOUNTING BRACKET AND END CAP
Level Device
End Cap Bracket
1. Remove cover plate, insert end cap bracket into
push bar assembly against mechanism case.
Level device, mark and drill two(2) holes for Bracket
Screws. Fasten end cap bracket screws to door.
End Cap
Screws
J
2. Insert cover plate, slide anti-rattle clip in position
(2" minimum from end), and attach end cap with
two(2) end cap screws.
09. INSTALL TOP LATCH AND ROD (SUITE)
Amount
to
Cut Off
Actual
Door
Opening
Height
Connecting
Bar
Connecting
Screw
Figure 2
3. Put connecting screw through round hole of connecting bar
and thread into top rod and tighten. See Figure 3
End Cap
C
Bracket Screws
2" Minimum
Cover Plate
Anti-Rattle Clip
End Cap
Rod
Rod
NOTE: Match notch of
connecting bar with
tab of rod before
tighten connecting
screw.
F
Figure 3
09. INSTALL TOP LATCH AND ROD
Top Latch
F
Latch
Screws
1. Install top latch with two(2) screws (sex bolts).
Adjust strike so that device latches without binding.
See Figure 1
2. Determine rod lengths as shown in Figure 2.
If necessary; cut end of rod and tap. See
"CUT TOP ROD / EXTEND TOP ROD" on page 10.
Sleeve
Connecting
Screws
Connecting
Bar
Notch
Tab
4. Assemble sleeve with rod. Thread top rod onto top
latch until first hole in connecting bar align with first
hole in retractor and fasten side screws.
7
H
Sex Bolts
Figure 1
Top Latch
Connecting
Bar
Second
Holes
Side