Advance acoustic 9087331020 Kullanım Kılavuzu - Sayfa 19

Yıkayıcı Advance acoustic 9087331020 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Advance acoustic 9087331020 20 sayfaları.

RECOVERY TANK REMOVAL

To check or charge the lead (WET) batteries, or to perform other procedures, it may be necessary to remove the recovery tank (16)
as shown below.
1.
Empty the recovery tank (16) as shown in the relevant paragraph.
2.
Drive the machine on a level floor.
3.
Make sure that the switches (41 and 42) are turned to "0".
4.
Remove the recovery water drain hose (11) from its holder.
5.
Grasp the recovery tank (A, Fig. 5) in the area (B) and slightly raise it.
6.
Disconnect the vacuum hose (C) from the tank.
7.
Disconnect the hose (D) from the tank vacuum grid.
8.
Remove the drain hose(E) through the slit, then remove the tank (A).
9.
Install the tank by performing steps 4 to 8 in the reverse order of removal.

MACHINE LONG INACTIVITY

If the machine is not going to be used for more than 30 days, proceed as follows:
1.
Perform the procedures shown in After Using the Machine paragraph.
2.
Disconnect the battery connector (8).

FIRST PERIOD OF USE

After the first 8 hours, check the machine fastening and connecting parts for proper tightening. Check the visible parts for integrity
and leakage.
A
B
D
C
Figure 5
INSTRUCTION FOR USE
B
E
9099602000 - SC450
ENGLISH
P100665
17