Care and Maintenance Instructions Model : Z2606
Removing and replacing a handle
MODEL SHOWN : Z2606
❶
Using a box cutter or similar sharp edged
tool, carefully remove the indice button.
❸
Remove the handle and handle extension
from the cartridge spline.
Available replacement handles:
-El Capitan Handle
-78 Mont Blanc Handle
-78A Mont Blanc Antique Crackle
-78B Mont Blanc Black
Further information Phone (03) 9761 4603
7
Unscrew the retaining screw with a Phillips
❷
head screw driver.
❹
To reassemble, reverse the disassembly
procedure, given above.
The retaining flange only needs to be hand tight.
NOTE: DO NOT USE A SHIFTER TIGHTEN BY HAND
ONLY !
Do not over tighten as this could damage the ceramic
cartridge!
NOTE: At any time, should the handle feel
loose, retighten the retaining flange and