CANTERBURY Z2606 Hızlı Başlangıç Kılavuzu - Sayfa 8
Banyo Armatürleri CANTERBURY Z2606 için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. CANTERBURY Z2606 10 sayfaları. Single hole mixer
Care and Maintenance Instructions Model : Z2606
MAINTENANCE FOR SINGLE HOLE/TWO LEVER TAP WARE WITH TWO LEVER DESIGN
INSTRUCTIONS FOR REPLACEMENT OF THE HO T OR COLD CARTRIDGE
Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or
kinking of supply hoses.
If the hand spray is leaking, do not replace the diverter. Service or replace the hand
Turn off the hot and cold supply lines to the tap.
❶
(Not shown).
spray if there is a continous leak.
Remove the handle as per the "Removing and
replacing handle" section on page 7.
Hand loosen the retaining flange A, once loose
unscrew and remove.
Install new cartridge.
❸
Secure the cartridge with a smooth jawed shifter.
Note: Do not over tighten as this could damage the ceramic cartridge!
Further information Phone (03) 9761 4603
8
Remove the cartridge with a smooth jawed 17mm
❷
shifter.
❹
Install hand lever and retaining flange. DO NOT USE
A SHIFTER TIGHTEN BY HAND ONLY!
Turn on supply line and test for leaks. (Not shown).
Continue.......