Advance Appliances EG9-U Kurulum ve Kullanım Kılavuzu - Sayfa 7

Kazan Advance Appliances EG9-U için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Advance Appliances EG9-U 12 sayfaları. Electric boiler 6, 9 & 12kw

Advance Appliances EG9-U Kurulum ve Kullanım Kılavuzu
USER INSTRUCTIONS
Set the programmer to match your own preferences for heating periods. The room
thermostat should be set at a comfort level, usually 20°C. The room thermostat should be
in a room where the radiator is locked on e.g. a hallway, study etc rather that a living room
or bedroom. The boiler is automatic and should give a trouble free life.
The green LED means that there is power to the boiler; it doesn't mean that the boiler is
actually heating the system. It does this when there is demand for heating through the
programmer and room thermostat.
If there is insufficient water in the system the red LED will be on continuously. Switch the
room thermostat off and on (making sure that the programmer is on) to start the boiler
up again, air may be present in the system. If the fault persists the system may need
recharging – consult your installer.
The case can be kept clean with a damp cloth.
FAILURE
The LED may flash red, indicating overheat. The unit is protected by the PCB controller in
addition to a thermomechanical device. The appliance will reset itself when it cools. If the
overheat recurs please ensure that the connection from the thermistor (on page 8) to the
PCB is soundly made. Check circulation is free in your heating system. A continuous red
LED relates to a no flow condition and air must be purged from the heating circuit or low
pressure, please charge system. Consult problem solving on page 9 if failure persists.
PROTECTION
In situations where this appliance may be subject to temperatures below 5°C (e.g. holiday
lets not occupied in winter etc) a frost thermostat can be linked to the control circuit. The
unit should always be installed in the main envelope of the property, never outside.
The eGlow can be safely installed in most situations, however, excessive moisture or
temperature extremes should be avoided.

PART NUMBERS

3Kw HEATER PODS
PCB ASSEMBLY
FLOW SWITCH
AUTO AIR VENT
AUTO BY PASS
THERMISTOR
PUMP
CONTACTOR
HIGH LIMIT THERMOSTAT
AA0401
AA0402
AA0403
AA0404
AA0405
AA0406
AA0407
AA0408
AA0409
7