a. MaIn On/OFF sWITCH
The switch has two ON positions marked with and "Manual".
The "Manual" position is for manual operation. In this position the
built-in remote control is by-passed.
The position is for operating the unit with the provided remote
control.
When in position the unit is operated with the ON and OFF
buttons of the remote control. When the switch is in the center
position the unit is off.
B. HeaTer On sWITCH
The HEAT ON/OFF SWITCH supplies power to the heater fan and
the heater element. When the switch is in the ON position the heater
operates if the thermostat calls for heat.
C. HeaTer THerMOsTaT COnTrOl
To adjust the temperature to your individual requirements, turn the
thermostat control clockwise all the way to turn on the heater. When
the room reaches the desired temperature, turn the thermostat knob
counter clockwise until you hear a click. Leave in this position to
maintain the room temperature at this setting. For additional heat,
turn clockwise until you hear the click again and the heater will turn
on.
reseTTInG THe TeMPeraTUre CUTOFF sWITCH
Should the heater overheat, an automatic cut out will turn the heater
off and it will not come back on without being reset. It can be reset by
switching the MAIN ON/OFF SWITCH to OFF and waiting 5 minutes
before switching the unit back on.
CaUTIOn
If you need to continuously reset the heater, unplug the unit and call
technical support at 1-888-346-7539.
nOTe
The heater may emit a slight, harmless odor when first used. This odor
is a normal condition caused by initial heating of internal heater parts and
will not occur again.