Baumer GNAMG Series Manuel - Sayfa 14

Aksesuarlar Baumer GNAMG Series için çevrimiçi göz atın veya pdf Manuel indirin. Baumer GNAMG Series 41 sayfaları. Inclination sensor with canopen interface

Baumer GNAMG Series Manuel
Heartbeat protocol
Example of a Heartbeat protocol
COB-ID
Data/Remote
701h
d
Heartbeat messages are composed of COB-ID and one byte. This byte is transmitting the NMT state.
0:
BootUp-Event
4:
Stopped
5:
Operational
127:
Pre-Operational
i.e. the inclination sensor is in pre-operational mode (7Fh = 127).
Important :
Only one of the above nodeguarding options can be active.
Default:
Heartbeat
Optional:
NodeGuarding (see object 2110)
Manual_GNAMG_CANopen_EN.doc
21.11.12
Byte 0
7Fh (127d)
14/41
Optionally the new Heartbeat protocol can
be utilized. Heartbeat is enabled if in object
2110h bit 5 is on "0". We recommend for
new applications the modern guarding
protocol heartbeat.
A "Heartbeat-Producer" produces a cyclic
heartbeat indication. One or more
"Heartbeat-Consumers" can receive this
heartbeat indication.
If there is no cyclic transmission of the
heartbeat message, this will result in a
„Heartbeat Event". The behaviour in case of
error is defined in object 1029h-1h
"Communication Error".
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany