Baumer GNAMG. 153P Series Manuel - Sayfa 16

Aksesuarlar Baumer GNAMG. 153P Series için çevrimiçi göz atın veya pdf Manuel indirin. Baumer GNAMG. 153P Series 19 sayfaları. Inclination sensor with profibus-dp interface

Baumer GNAMG. 153P Series Manuel

7. Terminal assignment and commissioning

7.1. Mechanical mounting

 Release both fastening screws of the bus cover.
 Carefully loosen the bus cover from the base plate and lift off in the axial direction.
 Firmly screw the base plate in place using the fastening holes.
 The bus cover must fully rest against the base plate. Any tolerances in mounting the bus cover onto the
base plate might affect the absolute inclination angle.
 Alignment of coordinates (y- / y+ / x- / x+) see following diagram.
Installation position – sensing range 15°, 30° und 60°
Baumer_GNAMG_Profibus_MA_EN
07.18
The two-dimensional inclination sensor with a sensing range of
15°, 30° and 60° must be mounted with the base plate in
horizontal position, i.e. parallel to the horizontal line.
The inclination sensor may also be installed upside down, i.e.
turned by 180°.
The sensor can be inclined both in lateral (X-axis) and
longitudinal (Y- axis) direction at the same time. For each
axis a separate measured value is provided.
As default parameter the inclinometer will apply the selected
sensing range to both the X and Y- axis, for example ±15° with
the zero passage being precisely in the horizontal line.
16/19
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany