Baumer IO-Link RR30 Kullanım Kılavuzu - Sayfa 30

Aksesuarlar Baumer IO-Link RR30 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Baumer IO-Link RR30 40 sayfaları. Radar sensor

Baumer IO-Link RR30 Kullanım Kılavuzu
Parameter name
Analog
Output.Distance@AnalogMin
Analog
Output.Distance@AnalogMax

4.9 Local User Interface

Different parameters are available to configure the local user interface which means the indication LEDs and
the local-teach-in (teach by wire)

Indication LEDs

4.9.1
Parameter name
LED Settings.Green.Mode
LED Settings.Yellow.Mode
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Short Description
Set the distance value in
mm at the minimum value of
the Analog Output
Set the distance value in
mm at the maximum value
of the Analog Output
Short Description
Switches the LED off, no
change of other function
Switches the LED off, no
change of other function,
Inverted: Pin high, LED off
On: Pin high, LED on
30/40
Rights
Unit / Allowed values
Limits:
rw
- 200 to 8000 mm
(Vers.: DAF0)
- 300 to 15000 mm
(Vers.: DAJ2)
- 400 to 80000 mm
(Vers.: DAO0)
Default =
- 200 mm
- 300 mm
- 500 mm
Limits:
rw
- 200 to 8000 mm
(Vers.: DAF0)
- 300 to 15000 mm
(Vers.: DAJ2)
- 400 to 80000 mm
(Vers.: DAO0)
Default =
- 6000 mm
- 12000 mm
- 60000 mm
Rights
Unit / Allowed values
On / Off
rw
Default: On
rw
On / Off / Inverted
Default: On
Frauenfeld, Switzerland
Baumer Electric AG