Baumer OG 90 Montaj ve Kullanım Talimatları - Sayfa 25
Medya Dönüştürücü Baumer OG 90 için çevrimiçi göz atın veya pdf Montaj ve Kullanım Talimatları indirin. Baumer OG 90 28 sayfaları. Incremental encoder
10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB058 - 11098546
Baumer_OG90_DE_EN_202209_MI_11098546 (22A3)
9...26 VDC (HTL- version C, TTL - version R)
5 VDC ± 5 % (TTL)
≤100 mA
1024...10000 (as ordered)
90° ±20°
40...60%
Zero pulse, width 90°
Optical
≤250 kHz
K1, K2, K0 + inverted
HTL-C
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL
ø115 mm
ø11 mm solid shaft
≤80 N axial
≤100 N radial
EURO flange B10
IP55
≤12000 rpm (mechanical)
1 Ncm
40 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-30...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 1 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
(only with option ATEX)
Terminal box
1.5 kg
10
Technical data
22