STANDARD HANDSET — UP/DOWN CONTROLS
First Generation (Control Box Labeled Choice)
A
Setting Upper Limit
1. Operate the system and stop at the preferred height of upper limit.
2. Press "+" and "–" together, and release "–" within 3 seconds (before it goes to reset mode)
3. Keep holding "+" for 5 seconds
4. Beep - setting completed!
Setting Lower Limit
1. Operate the system and stop at the preferred height of lower limit.
2. Press "+" and "–" together, and release "+" within 3 seconds (before it goes to reset mode)
3. Keep holding "–" for 5 seconds
4. Beep - setting completed!
Clean Upper Limit:
1. Go the upper limit has been set
2. Press "+" and "–" together, and release "–" within 3 seconds (before it goes to reset mode)
3. Keep holding "+" for 5 seconds
4. Beep - cancellation completed!
Clean Lower Limit:
1. Go the lower limit has been set
2. Press "+" and "–" together, and release "+" within 3 seconds (before it goes to reset mode)
3. Keep holding "–" for 5 seconds
4. Beep - cancellation completed!
Reset (Limitation of Reset)
1. The reset position will still be the mechanical limit (TL fully retracted). After reset, the user has to extend
the column to be higher than the preset lower limit to operate normally.
2. Within the range between reset positon and preset lower limit, only moving up is allowed until the height
exceeds the preset lower limit. (Moving down could not be operated)
3. There's a beep as a reminder when the height exceeds the preset lower limit.
KINEX USER GUIDE | 2
A. Up Button
B. Down Button
B
Height Ranges:
2-Stage Legs: 27"-46.7"
3-Stage Legs: 22"-48"