Drawmer 1970 Operatör El Kitabı - Sayfa 4
Kayıt Ekipmanları Drawmer 1970 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. Drawmer 1970 12 sayfaları. Dual fet compressor & pre-amplifier
The 1970 is designed for standard 19" rack mounting and occupies 2U of rack space. Fibre or plastic
washers may be used to prevent the front panel becoming marked by the mounting bolts.
- Care should be taken in the choice of positioning. The unit should not be mounted where other
equipment obstructs the normal air flow. The unit should not be situated near any heat source, such
as a radiator, stove or a high power amplifier that would generate heat.
- The appliance should not be operated near any water or in a location where moisture might be
present.
- Always connect the mains earth to the unit.
If the 1970 is to be continuously moved from one location to another, we suggest using additional support in
the rack at the rear of the unit.
The unit will have been supplied with a power cable suitable
for domestic power outlets in your country. For your own safety
it is important that you use this cable. The unit should always
be connected to the mains supply earth using this cable, and
no other.
If for some reason the unit is to be used at a mains
input operating voltage which is different to that
as supplied, the following procedure must be
carried out.
1: Disconnect the unit from the mains.
2: Remove the two screws holding the voltage
selection cover-plate.
3: Remove the cover plate and slide the switch
fully to its opposite end.
4: Rotate the cover plate one half turn (180
degrees) and refit the two screws.
5: Replace with a correctly rated fuse for the
selected operation voltage in the IEC socket:
230V-T250mA and 115V-T500mA
6: Re-connect to mains power source.
Never disconnect the earth
from the mains supply
4
INSTALLATION
POWER CONNECTION
DRAWMER 1970 O
PERATOR'S
COVER-PLATE
IEC SOCKET FUSE DRAWER
M
ANUAL