TROUBLE SHOOTING
Condition
Motor fails to run
Faulty wiring to motor
Grease gun fails to
dispense grease
Loss of prime
Grease gun continues
to lose prime
Ball check valve kit is
not functioning
Follower may be binding in
grease barrel assembly
Battery fails to take a charge
NSW
TEL: (02) 9939 0711
FAX: (02) 9939 0411
Visit our website at
Possible Cause
Battery needs charging
Grease barrel assembly is out of grease
Air may be trapped in several locations
Charger may not have power
Battery may be bad
QLD/PNG
VIC/TAS
TEL: (07) 3204 9166
TEL: (03) 8787 8288
FAX: (07) 3204 1224
FAX: (03) 8787 8266
www.alemlube.com.au
Corrective Action
Recharge battery
Remove battery, disassemble handle and check
wiring for loose connection.
Check that grease barrel assembly has grease
Repeat priming operation
Empty grease barrel in container after bulk filling
Assemble, refill and repeat priming instructions
Remove Item 38;39;40, clean and inspect ball seat area
Step1. Replace grease barrel assembly.
Step 2. Disassemble grease barrel assembly and clean
Be sure that follower has properly entered the
grease cartridge
Or verify that the follower is not caught on the rim
of the grease cartridge
Check that receptacle has power
Replace battery
WA
SA/NT
TEL: (08) 9209 3066
TEL: (08) 8241 7111
FAX: (08) 9209 3933
FAX: (08) 8241 7011
Email - [email protected]