Alen AMS12 12000 BTU AND 13.5 SEER Kurulum Kılavuzu - Sayfa 10
Klima Alen AMS12 12000 BTU AND 13.5 SEER için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Alen AMS12 12000 BTU AND 13.5 SEER 17 sayfaları. Split type room air conditioner 9000 btu and 14.5 seer/12000 btu and 13.5 seer
EvAPORATOR INSTALLATION (INDOOR)
2) Connective Pipe and Drainage Installation
i) Drainage
Run the drain hose downward.
Do not install the drain hose as illus-
trated below.
Do not form a rise
ii) Connective Pipe
Pipe holder
Pipe cover
Right piping
Right back piping
a) For the left-hand and right-hand piping,
remove the pipe cover from the side panel.
Explain to the customer that the pipe cover
must be kept as it may be used if the air
conditioner is moved to another location.
b) For the left-hand and rear-left-hand pip-
ing, install the piping as shown. Bend the
connective pipe to be
placed at a height of 1 5/8 inches
or less from the wall.
Evaporator (Indoor) Unit outline
c) Fix the end of the connective pipe.
(Refer to Tightening Connection in
Refrigerant Piping Connection).
Do not put the hose
end into water
Pipe Cover
Left piping
Left back piping
Connective Pipe
iii) Piping and Bandaging
Wind the Connective cable, drain hose
and wiring tape securely, evenly as
shown below.
Evaporator (Indoor) Unit
Connective Cable
Drain Hose
3) Evaporator (Indoor)
Unit Installation
iii) Insert a spacer between the evaporator
(indoor) unit and the wall bracket to sepa-
rate the bottom of the unit from the wall.
iv) Push the lower part of the evaporator
(indoor) unit up on the wall. Then move
the evaporator (indoor) unit from side to
side, up and down to check if it is hooked
.
securely
9
Ponding Box
Pipe Room
Connective Pipe
Wrapping Belt
i) Pass the piping through
the hole in the wall
ii) Put the upper claw at
the back of the installation
plate, move the evaporator
(indoor) unit from side to
side to see if it is securely
hooked.